½ًَ¸²¶سم

online service
hotline
Mobile: 18936757575
Mobile: 13915157170
Mobile: 18052362775
After sales: 13151342466
Phone: 0517-86951208
Phone: 0517-86856332
Phone: 0517-86997027

Manager Pan, Manager Gu

hot key words:

Magnetic plate level gauge magnetic level gauge magnetic float level gauge magnetic column level gauge magnetic float level gauge

Current column: Magnetic level gauge

High temperature and high pressure magnetic flap liquid level gauge

The high-temperature and high-pressure magnetic flap liquid level gauge is suitable for the measurement and control of the liquid and boundary levels of high-temperature and high-pressure liquid containers. Clearly indicate the height of the liquid level, the display is intuitive and eye-catching, the indicator is completely isolated from the storage tank, safe to use, reasonable design, simple structure, convenient and reliable installation, stable performance, long service life, low maintenance costs, easy installation and maintenance, etc. .
Quality Assurance: Signing service, 2 years warranty. After-sales service: fast response, patient guidance, careful service, genuine treatment

  • product description

High temperature and high pressure magnetic flap liquid level gauge.jpg

It is therefore worth noting that these two independent discussions focus on the theoretical categories currently considered to be related to the strong, weak, and electromagnetic interactions of elementary particles. The simpler theory explains how the ideas explained in $ 92 and $ 3 are synthesized. This theory was originally proposed by t Hooft (1974) and Polyakov (1974). In $ 4, we will discuss this theory, especially the solutions that Hooft and Polyakov focus on. This has a natural explanation as an extended object, providing an explicit Dirac monopole model over large distances, but its short-range structure has been modified to give it limited energy. We carefully explained how electromagnetics is embedded in the theory and how the topological nature of the asymptotic value of the Higgs field leads to the Dirac quantification condition of magnetic charge. We deduced the lower bound of the mass of any solution of this theory. Based on its electric and magnetic charges, it was first discovered by Bogomolny, and discussed the exact solution found by Prasad and Sommerfield at the limit of the self-interaction of the Higgs field disappearing. This article also discusses Dyons and candidates for the magnetic current inside the monopole.

Overview of high temperature and high pressure magnetic flap liquid level gauge:
The high-temperature and high-pressure magnetic flap liquid level gauge is suitable for the measurement and control of the liquid and boundary levels of high-temperature and high-pressure liquid containers. Clearly indicate the height of the liquid level, the display is intuitive and eye-catching, the indicator is completely isolated from the storage tank, safe to use, reasonable design, simple structure, convenient and reliable installation, stable performance, long service life, low maintenance costs, easy installation and maintenance, etc. .
Users can use remote transmitters according to the needs of the project, which can realize local digital display and output standard remote electric signals of 4-20mA to meet the needs of recording instruments or industrial process control. It can also be used with magnetic control switches or proximity switches to control liquid level monitoring and alarm or liquid inlet and outlet equipment.

Technical parameters of high temperature and high pressure magnetic flap level meter:
Measuring range: 200 ……. ~ 15000㎜ (level gauges exceeding 6000mm or transportation conditions that do not allow the length can be purchased and manufactured in stages)
Working pressure: 6.3, 10.0, 16.0, 25.0MPa;
Medium density difference: ≥.0.15g / cm3 (measurement boundary)
Medium viscosity: ≤0.4Pa ،¤ S;
Process connection: DN20 / 25 PN1.0 (implements standard HG20592 ~ 20635-97), if other standards are required, it can be manufactured according to customer requirements.
Wetted material: 316SS, 316L, etc.
(Select according to the chemical nature of the medium and the temperature and pressure of use);
Float material: 316SS, 316L, titanium, etc.
Selection table of high temperature and high pressure magnetic flap liquid level gauge:
Level gauge
Types of
□ Local display □ Output 4-20mA □ Upper and lower limit alarm (switch form: normally open or normally closed, holding type, explosion-proof type)
□ Output 4-20mA and upper and lower limit alarms □ HART protocol □ RS485 bus
Operating temperature □ -20 ~ 450 ℃ □ ℃ (according to customer requirements)
Measuring range □ L = ㎜ (according to customer requirements: 200 ……. ~ 15000㎜)
Measurement medium □ (according to customer requirements)
Medium density □ g / cm3 (provided by customer: ≥.0.5g / cm3)
design pressure □ ≤6.3Mpa □ ≤10.0Mpa □ ≤25Mpa □ Other Mpa
Actual pressure □ ≤6.3Mpa □ ≤10.0Mpa □ ≤25Mpa □ Other Mpa
Process connection □ DN20 PN1.0 □ DN25 PN1.0 □ Others: DNPN (according to customer requirements)
other request □ Explosion-proof (Explosion-proof type) □ Other

Working principle of high temperature and high pressure magnetic flap liquid level gauge:  
The flip box outside the main body is urged by the inner float of the main body (with a directional magnetic source, which is developed according to different media and pressures) to flip the flip and display red and white colors, and indicate different liquid surface heights as the float moves. On the left side of the indicator is equipped with a conspicuous graduation ruler, which makes the indication of the liquid level more clear.


Product Features of High Temperature and High Pressure Magnetic Flap Level Gauge
The components of the high-temperature and high-pressure magnetic flap level gauge are made of 1Cr18Ni9Ti, 316L, 304 stainless steel and lined with PTFE, PVC, PP and other imported components. They have excellent reliability, stability and corrosion resistance. Its characteristics are very significant:
※ Simple design, compact, sturdy and reliable, long life, no maintenance workload can be installed and used indoors and outdoors for many years;
※ The measuring tube is completely isolated from the liquid level display part, the liquid level transmitter, and the alarm switch in terms of pressure and gas resistance;
※ Wide working pressure range, withstand pressure from vacuum to 42Mpa; corrosion resistance ≤ 2.5Mpa;
※ Wide working temperature range, suitable for -160 ~ + 450 ℃;
※ Widely used for strong and weak corrosive, flammable and explosive, toxic, strong radioactive, agitated, dirty liquid level measurement;
※ Each model can be equipped with a magnetic alarm switch to achieve automatic control of high or low liquid level or alarm;
※ Each model can be equipped with 4 ~ 20mADC liquid level sensor to realize long-distance centralized measurement and control.

Selection of high temperature and high pressure magnetic flap liquid level gauge


model
UHZ-517
Structural features
Wetted material
Measuring range
(mm)
Applicable medium conditions
Flange connection (mm)
Weight (kg)
temperature
(℃)
pressure
(Mpa)
density
g / cm 3
Viscosity
()
DN
PN
Basic
weight
Lengthen
Basic
weight
C10
Standard type
1Cr18Ni
9Ti0Cr18Ni9
(304)
300-
8000
-20
+150
0-2.45
0.5-2
≤0.04
25
1.0
1.6
6
5
C11
High pressure
300-
8000
-20
+150
2.45-9.6
0.5-2
≤0.04
25
2.5
4.0
6
6
C12
High temperature type
High pressure
300-
8000
-20
+350
2.45-9.6
0.5-2
≤0.04
25
6.3
1.0
6
6
C13
Low temperature model
(Frost proof)
300-
3500
> -40
0-2.45
0.5-2
≤0.04
25
1.6
2.5
6
7.5
C14
Liquid ammonia, liquid
LPG
Dedicated
300-
15000
-20
+150
0-2.45
0.45-0.7
≤0.05
25
2.5
6.5
6
C15
Corrosion-resistant
00Cr17Ni14Mo2
(316L)
300-
8000
-20
+150
0-2.45
0.5-2
≤0.04
25
1.6
6
5
C16
Anticorrosive
PP outer glass
Glass steel
PP
300-
5000
20
+100
0-0.6
0.5-2
≤0.04
32
1.6
3
3
C17
Anticorrosive
PVC outer layer
FRP)
U-PVC
300-
5000
20
+60
0-0.5
0.5-2
≤0.04
32
1.6
3
3
C18
Anticorrosive
ABS
300-
5000
-20
+120
0-0.6
0.5-2
≤0.04
32
1.0
3
3
C19
Anticorrosive
Stainless steel
Lining PP)
PP
300-
15000
-20
+100
0-1.0
0.5-2
≤0.04
25
1.6
4
5
C20
Anticorrosive
PE
300-
5000
20
+40
0-0.6
0.5-2
≤0.04
25
1.6
6
7
C21
Steam jacket
Heating type
1Cr18Ni9Ti
300-
15000
-20
+150
0-2.45
0.5-2
≤0.05
32
1.6
6
8
C22
high viscosity
Media type
0Cr18Ni9
(304)
300-
15000
-20
+150
0-2.45
0.5-2
≤0.05
32
1.6
6
5
C23
Food specialty
Type
1Cr18Ni9Ti
300-
15000
-20
+150
0-1.6
0.5-2
≤0.05
50
1.6
7
5
□□
Supporting instruments and accessories
O
Blind flange, without drain valve
L
Sewage valve at the bottom of the level gauge
O
No level alarm switch
H
High-level alarm switch AK-3, with memory function, fault is not eliminated, signal is not eliminated
L
Low-level alarm switch AK-4, with memory function, failure is not eliminated, signal is not eliminated
B
Fully equipped with high and low alarm switches, with memory function AK-3 and AK-4
G
High alarm switch, area alarm AK-1
With DF-1 type conversion amplifier
One PF113A socket




JTX-012-22F high power relay (single point: one, two points) only PF083A socket
D
Low alarm switch, area alarm AK-1
Q
Fully equipped with high and low alarm switches, area alarm AK-1 type platform
S
High and low integrated alarm switch, area alarm AK-2
O
No level control switch
H
Upper limit control switch, single-point reed CK-1
L
Lower limit control switch, single point reed CK-1
B
Fully equipped with upper and lower limit control switches, single point reed CK-1 type
W
Integrated upper and lower limit control switches, double-point reed CK-2
T
Upper limit control switch, Hall type sensor CK-3
L
Lower limit control switch, Hall type sensor CK-4
E
Fully equipped with upper and lower limit control switches, Hall type sensor CK-3
C
Integrated upper and lower limit control switches, Hall type sensor CK-4
O
No remote transmitter device
R
With LB bundled transmitter, output two-wire system 4-20mADC
S
Hydrostatic remote transmitter, (URS-100) output two-wire 4-20mADC
O
Ordinary waterproof type
B
Intrinsically safe ibⅡCT4, can be equipped with Zener barrier or IS4041-Ex barrier
Bd
Flameproof dⅡCT4
O
Not equipped with remote transmission display instrument
A
Digital, light column display adjustment alarm XGTH-510 (vertical)
B
Digital, light column display adjustment alarm XGTA-810 (horizontal)
C
Digital display adjustment alarm XMTA-810 (horizontal)
E
Dual-beam liquid level display XGH-202 (vertical)
D
Intelligent level / capacity (weight) display regulator XMT-620 (horizontal)
-□□□□
Measuring range (mm)
-□□
) Medium density (g / cm 3 )
-
D
Open pressure container
Working pressure (MPa)

固定,否则会影响磁翻板液位计的正常工作; 1. The magnetic flap liquid level meter body is not allowed to have magnetic conductive material around, disable iron wire fixing, otherwise it will affect the normal operation of the magnetic flap liquid level meter;
2. If the user adopts the heat tracing pipeline by himself, non-magnetic materials must be selected, such as copper pipes. The heat tracing temperature is determined according to the condition of the medium;
3. The magnetic flap liquid level gauge must be installed vertically, and a ball valve should be installed between the magnetic flap liquid level gauge and the container's lead tube to facilitate maintenance and cleaning;
4. The medium should not contain solid impurities or magnetic substances, so as not to cause jams to the float;
5. Before use, first use the correction magnetic steel to set the small balls below zero to red and other balls to white;
6. Open the bottom flange and install the magnetic float (note: the heavy end with the magnetic end is up and cannot be inverted.);
8. According to the condition of the medium, the main pipe should be cleaned from time to time to remove impurities;
9. For liquid level gauges that exceed a certain length (ordinary type> 3 meters, anti-corrosion type> 2 meters), the intermediate reinforcement flange or ears need to be added for fixed support to increase strength and overcome their own weight
10. The installation position of the magnetic flap liquid level meter should avoid or stay away from the inlet and outlet of the material medium to avoid rapid changes in the local area of the material fluid and affect the accuracy of the liquid level measurement;
11. When equipped with remote transmission supporting instruments, the following should be done:
(1) The remote transmission supporting instrument should be close to the main pipe of the level gauge and fixed with stainless steel hoop (iron is prohibited) ;
(2) The sensing surface on the remote transmission supporting instrument should face and close to the main duct;
(3) The zero position of the remote supporting instrument should be on the same level line as the zero indication of the level gauge;
(4) The connection between the remote transmission supporting instrument and the display instrument or industrial control computer should be laid separately through a protective tube or a shielded two-core cable;
(5) After laying the wire entry hole of the junction box, it is required to be well sealed to prevent the invasion of remote transmission equipment from working properly due to the invasion of rainwater and moisture.
download Google:
1. Model specifications 2. Name and density of the tested medium
3. Working pressure 4. Working temperature 5. Measuring range 6. Connecting flange (standard) 7. Supporting instruments 8. Special requirements

Installation and maintenance of high temperature and high pressure magnetic flap liquid level gauge
Related Products
  • 防腐磁翻板液位计

    Anticorrosive magnetic plate level gauge

  • 耐酸碱磁翻板液位计

    Acid and alkali resistant magnetic plate level gauge

  • 不锈钢磁翻板液位计

    Stainless steel magnetic level gauge

  • 4-20mA输出磁翻板液位计

    4-20mA output magnetic flap level gauge

  • 上下限报警磁翻板液位计

    Upper and lower limit alarm magnetic flap liquid level gauge

  • 带报警磁性浮子液位计

    Magnetic float level gauge with alarm

  • 硝酸液位计

    Nitric acid level gauge

  • 远传型磁性浮子液位计

    Remote transmission magnetic float level gauge

  • 侧装式磁性浮子液位计

    Side mounted magnetic float level gauge

  • 浓硫酸液位计

    Concentrated sulfuric acid level gauge

Jiangsu Meant Automation Instrument Co., Ltd.

Mobile: 18936757575 Manager Jiang (same number on WeChat)
Mobile: 13915157170 Manager Pan (same number on WeChat)
Mobile phone: 18052362775 Manager Gu (same number on WeChat)
Jiangsu, Zhejiang and Shanghai agents: 13151342466 Manager Wei (same number on WeChat)
Technology: 13151342466 Manager Zhang (WeChat same number)
Phone: 86-0517-86951208
Phone: 0517-86997027
Phone: 0517-86856332
Fax: 86-0517-86997010
Address: Shenhua Avenue, Jinhu County, Huaian City, Jiangsu Province

Copyright Jiangsu Meant Automation Instrument Co., Ltd. 苏 ICP 备 17042927 号 -2