Magnetic plate level gauge magnetic level gauge magnetic float level gauge magnetic column level gauge magnetic float level gauge

Current column: Magnetic level gauge

Remote Transmission Magnetic Flap Level Meter

The remote magnetic flap level meter is a combination of the basic type and the remote transmitter, which can realize the remote signal transmission, liquid level alarm and control functions. The intuitive, eye-catching, cost-effective, temperature-resistant, pressure-resistant, anti-corrosion, and explosion-proof features of the XY-UHZ magnetic flap liquid level gauge make it widely used in the production process of power, petroleum, chemical, metallurgy, environmental protection and other industries. Level measurement and automatic control.
Quality Assurance: Signing service, 2 years warranty. After-sales service: fast response, patient guidance, careful service, genuine treatment

  • product description

Remote transmission magnetic flap level gauge.Jpg

In a sense, the subject of $ 5 is the gradual degradation of the Higgs field and the broken symmetry group G when discussing the macroscopic nature of the solution. We end with everything represented by H, and then we can associate the Wu and Yang Higgs field formalism we have used, and only the exact symmetry group H appears in it.
At $ 6, we considered the microscopic nature of the monopoles, their internal structure. Although the Higgs field and the fully symmetric group G now play a key role in obtaining finite energy solutions, what we can say here is not complete. In the case of toft-polyakov, the solutions found and analyzed often have some spherical symmetry that we discuss. We reviewed the corresponding possibility that G = SU (3) discusses H = U (2) and H = S0 (3). The characteristics of these SU (3) solutions are obtained in a more general context through the quantization conditions of spherically symmetric monopoles that we have derived. We specifically discuss the relationship of these results to Wilkinson and Goldhaber analysis.

Overview of remote transmission magnetic level gauge:
The remote magnetic flap level meter is a combination of the basic type and the remote transmitter, which can realize the remote signal transmission, liquid level alarm and control functions. The intuitive, eye-catching, cost-effective, temperature-resistant, pressure-resistant, anti-corrosion, and explosion-proof features of the XY-UHZ magnetic flap liquid level gauge make it widely used in the production process of power, petroleum, chemical, metallurgy, environmental protection and other industries. Level measurement and automatic control.

产品特点: Product Features of Remote Magnetic Flip Level Meter :
It is suitable for liquid level and boundary measurement of pressure vessels. It can integrate on-site instructions, remote transmission and control alarm.
The instructions are novel, the readings are intuitive and eye-catching, and the viewing angle can be changed according to the user's convenience.
Large measuring range, not limited by the height of the tank.
The indicating mechanism is completely isolated from the measured medium, so it is well sealed, highly reliable and safe to use.
High temperature resistance, non-fading ceramic columns can be used.
Simple structure, easy installation and low maintenance cost.
A. Basic type:
Measuring range: 300 ~ 15000mm Measuring accuracy: 5.0mm, 10mm
Working temperature: -40 ~ 250 ℃ (ABS PP-R, PVC: -40 ~ 80 ℃) Special type can reach 450 ℃
Working pressure: ≤ 2.5MPa (more than 2.5MPa can be set separately) Anticorrosive type ≤ 0.6MPa
Medium viscosity: ≤1st (10-4m2 / s) Medium density: ≥450kg / m3
Medium density difference: ≥ 150kg / m3 Sewage interface: ZG1 / 2 "(inside)
Ambient vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm following speed: ≤ 0.08m / s
Wetted material: stainless steel (1Cr18Ni9Ti, 316, 316L)
Stainless steel lined with PTFE (1Cr18Ni9Ti lined with PTFE,)
PVC plastic (polyvinyl chloride), PP-R, ABS
Connection process: side-mounted HG20592-97 DN25 PN4.0 (or user specified)
Top-mounted HG20592-97 DN100 PN1.6 (or user specified)
Jacket flange HG20592-97 DN15 PN1.6 (or user specified)
B. Remote transmission device:
Output signal: 4 ~ 20mA Load impedance: 350Ω (at 24VDC)
Power supply: 18 ~ 30VDC (rated 24VDC) Ambient temperature: -40 ~ 80 ℃
Relative humidity: ≤90% RH Power consumption: 0.5W
Intrinsically Safe: ibIICT4 Flameproof: dIIBT4
C. Control alarm switch output type: normally open normally closed switch signal Alarm accuracy: + 10mm
Ambient temperature: -40 ~ 80 ℃ Working life: ≥105 times Outlet interface: M201.5 or internal thread 3/4 ″
The characteristics of the remote magnetic flap level gauge are suitable for the liquid level and boundary measurement of pressure vessels, which can integrate on-site instructions, remote transmission and control alarm.
The instructions are novel, and the readings are intuitive and eye-catching. The viewing angle can be changed according to the user's convenience.
Large measuring range, not limited by the height of the tank.
The indicating mechanism is completely isolated from the measured medium, so it is well sealed, highly reliable and safe to use.
High temperature resistance, non-fading ceramic columns can be used.
Simple structure, easy installation and low maintenance cost.

Principle of remote transmission magnetic level gauge:
The magnetic level gauge produced by our company is developed based on the principle of buoyancy and magnetic coupling. When the liquid level in the tested container rises and falls, the float in the main pipe of the level gauge also rises and falls. The permanent magnetic steel in the float is transmitted to the on-site indicator through magnetic coupling, which drives the red and white flip columns to turn 180 degrees. When the liquid level rises, the flip column changes from white to red. When the liquid level drops, the flip column changes from red to white. The red and white levels of the indicator are the actual height of the liquid level in the container, thereby achieving the liquid level. Instructions.
The electric signal remote transmission of the magnetic flap liquid level gauge produced by our company is realized by the combination of the basic type and the liquid level remote transmission device. The liquid level remote transmission device is composed of UR type resistance sensor and UB type R / I conversion module. The sensor of this transmitter is fixed on the outside of the main conduit of the UHZ type magnetic flap liquid level gauge in a bundled form so that it is at the liquid level. In the same magnetic coupling system. When the magnetic float moves up and down with the liquid level, the reed switch corresponding to the liquid level is attracted by the magnetic field in the float, the resistance value of the resistance chain changes, and the changed resistance signal is converted into a two-wire 4-20mADC standard through a conversion module. Signal output. This signal can be conveniently used with electric type III instruments and displays, and can also be used with light column indicators and digital display adjustment alarms to achieve the purpose of display, control, adjustment and alarm.
The magnetic flap level meter produced by our company is controlled and alarmed through a reed switch or mercury contact switch to act on the given value of the liquid level, so as to achieve the purpose of liquid level alarm, control and accident interlocking.


Main technical indicators of remote transmission magnetic level gauge
mm ): 300 19000 1. Measuring range ( mm ): 300 to 19000
g/cm3 ): 0.51090 2 2. Medium density ( g / cm3 ): 0.51090 to 2
3 , medium viscosity:
-40 350 4. Working temperature : -40 350
MPa ): ≤32 5. Pressure level ( MPa ): ≤32
mm ): ≤10 6. Measurement accuracy ( mm ): ≤ 10
7 , installation: side-mounted, top-mounted, bottom-mounted  
IP65 8. Protection level: IP65
ibⅡCT4 (本安型)、 dⅡBT4 (隔爆型) 9. Explosion-proof grade: ibⅡCT4 ( intrinsically safe type), dⅡBT4 (explosion-proof type)  
4 20mA 或开关量 10. Transmission method: 4 20mA or switch value  
PN4.0 DN25 HG20593 (侧装式) 11. Interface flange: PN4.0 DN25 HG20593 (side mounted)  
HG20593 (顶装式、底装式),可以根据用户的需要特殊定制。 PN1.0 DN100 HG20593 (top-mounted, bottom-mounted), can be customized according to user's needs.


选型 Selection of remote transmission magnetic level gauge


model
UHZ-517
Structural features
Wetted material
Measuring range
(mm)
Applicable medium conditions
Flange connection (mm)
Weight (kg)
temperature
(℃)
pressure
(Mpa)
density
g / cm 3
Viscosity
()
DN
PN
Basic
weight
Lengthen
Basic
weight
C10
Standard type
1Cr18Ni
9Ti0Cr18Ni9
(304)
300-
8000
-20
+150
0-2.45
0.5-2
≤0.04
25
1.0
1.6
6
5
C11
High pressure
300-
8000
-20
+150
2.45-9.6
0.5-2
≤0.04
25
2.5
4.0
6
6
C12
High temperature type
High pressure
300-
8000
-20
+350
2.45-9.6
0.5-2
≤0.04
25
6.3
1.0
6
6
C13
Low temperature model
(Frost proof)
300-
3500
> -40
0-2.45
0.5-2
≤0.04
25
1.6
2.5
6
7.5
C14
Liquid ammonia, liquid
LPG
Dedicated
300-
15000
-20
+150
0-2.45
0.45-0.7
≤0.05
25
2.5
6.5
6
C15
Corrosion-resistant
00Cr17Ni14Mo2
(316L)
300-
8000
-20
+150
0-2.45
0.5-2
≤0.04
25
1.6
6
5
C16
Anticorrosive
PP outer glass
Glass steel
PP
300-
5000
20
+100
0-0.6
0.5-2
≤0.04
32
1.6
3
3
C17
Anticorrosive
PVC outer layer
FRP)
U-PVC
300-
5000
20
+60
0-0.5
0.5-2
≤0.04
32
1.6
3
3
C18
Anticorrosive
ABS
300-
5000
-20
+120
0-0.6
0.5-2
≤0.04
32
1.0
3
3
C19
Anticorrosive
Stainless steel
Lining PP)
PP
300-
15000
-20
+100
0-1.0
0.5-2
≤0.04
25
1.6
4
5
C20
Anticorrosive
PE
300-
5000
20
+40
0-0.6
0.5-2
≤0.04
25
1.6
6
7
C21
Steam jacket
Heating type
1Cr18Ni9Ti
300-
15000
-20
+150
0-2.45
0.5-2
≤0.05
32
1.6
6
8
C22
high viscosity
Media type
0Cr18Ni9
(304)
300-
15000
-20
+150
0-2.45
0.5-2
≤0.05
32
1.6
6
5
C23
Food specialty
Type
1Cr18Ni9Ti
300-
15000
-20
+150
0-1.6
0.5-2
≤0.05
50
1.6
7
5

□□
Supporting instruments and accessories
O
Blind flange, without drain valve
L
Sewage valve at the bottom of the level gauge
O
No level alarm switch
H
High-level alarm switch AK-3, with memory function, fault is not eliminated, signal is not eliminated
L
Low-level alarm switch AK-4, with memory function, failure is not eliminated, signal is not eliminated
B
Fully equipped with high and low alarm switches, with memory function AK-3 and AK-4
G
High alarm switch, area alarm AK-1
With DF-1 type conversion amplifier
One PF113A socket




JTX-012-22F high power relay (single point: one, two points) only PF083A socket
D
Low alarm switch, area alarm AK-1
Q
Fully equipped with high and low alarm switches, area alarm AK-1 type platform
S
High and low integrated alarm switch, area alarm AK-2
O
No level control switch
H
Upper limit control switch, single-point reed CK-1
L
Lower limit control switch, single point reed CK-1
B
Fully equipped with upper and lower limit control switches, single point reed CK-1 type
W
Integrated upper and lower limit control switches, double-point reed CK-2
T
Upper limit control switch, Hall type sensor CK-3
L
Lower limit control switch, Hall type sensor CK-4
E
Fully equipped with upper and lower limit control switches, Hall type sensor CK-3
C
Integrated upper and lower limit control switches, Hall type sensor CK-4
O
No remote transmitter device
R
With LB bundled transmitter, output two-wire system 4-20mADC
S
Hydrostatic remote transmitter, (URS-100) output two-wire 4-20mADC
O
Ordinary waterproof type
B
Intrinsically safe ibⅡCT4, can be equipped with Zener barrier or IS4041-Ex barrier
Bd
Flameproof dⅡCT4
O
Not equipped with remote transmission display instrument
A
Digital, light column display adjustment alarm XGTH-510 (vertical)
B
Digital, light column display adjustment alarm XGTA-810 (horizontal)
C
Digital display adjustment alarm XMTA-810 (horizontal)
E
Dual-beam liquid level display XGH-202 (vertical)
D
Intelligent level / capacity (weight) display regulator XMT-620 (horizontal)
-□□□□
Measuring range (mm)
-□□
) Medium density (g / cm 3 )
-
D
Open pressure container
Working pressure (MPa)

Proper assembly, use and maintenance of remote transmission magnetic level gauge
1. The magnetic flap liquid level meter body is not allowed to have magnetic conductive material around, disable iron wire fixing, otherwise it will affect the normal operation of the magnetic flap liquid level meter;
2. If the user adopts the heat tracing pipeline by himself, non-magnetic materials must be selected, such as copper pipes. The heat tracing temperature is determined according to the condition of the medium;
3. The magnetic flap liquid level gauge must be installed vertically, and a ball valve should be installed between the magnetic flap liquid level gauge and the container's lead tube to facilitate maintenance and cleaning;
4. The medium should not contain solid impurities or magnetic substances, so as not to cause jams to the float;
5. Before use, first use the correction magnetic steel to set the small balls below zero to red and other balls to white;
6. Open the bottom flange and install the magnetic float (note: the heavy end with the magnetic end is up and cannot be inverted.);
8. According to the condition of the medium, the main pipe should be cleaned from time to time to remove impurities;
9. For liquid level gauges that exceed a certain length (ordinary type> 3 meters, anti-corrosion type> 2 meters), the intermediate reinforcement flange or ears need to be added for fixed support to increase strength and overcome their own weight;
10. The installation position of the magnetic flap liquid level meter should avoid or stay away from the inlet and outlet of the material medium to avoid rapid changes in the local area of the material fluid and affect the accuracy of the liquid level measurement;
11. When equipped with remote transmission supporting instruments, the following should be done:
(1) The remote supporting instrument should be close to the main pipe of the level gauge and fixed with stainless steel hoop (iron is prohibited);
(2) The sensing surface on the remote transmission supporting instrument should face and close to the main duct;
(3) The zero position of the remote supporting instrument should be on the same level line as the zero indication of the level gauge;
(4) The connection between the remote transmission supporting instrument and the display instrument or industrial control computer should be laid separately through a protective tube or a shielded two-core cable;
(5) After laying the wire entry hole of the junction box, it is required to be well sealed to prevent the invasion of remote transmission equipment from working normally due to the invasion of rainwater and moisture. The junction box should be covered in time after the maintenance or commissioning is completed.

Related Products
  • 防腐磁翻板液位计

    Anticorrosive magnetic plate level gauge

  • 耐酸碱磁翻板液位计

    Acid and alkali resistant magnetic plate level gauge

  • 不锈钢磁翻板液位计

    Stainless steel magnetic level gauge

  • 4-20mA输出磁翻板液位计

    4-20mA output magnetic flap level gauge

  • 上下限报警磁翻板液位计

    Upper and lower limit alarm magnetic flap liquid level gauge

  • 带报警磁性浮子液位计

    Magnetic float level gauge with alarm

  • 硝酸液位计

    Nitric acid level gauge

  • 远传型磁性浮子液位计

    Remote transmission magnetic float level gauge

  • 侧装式磁性浮子液位计

    Side mounted magnetic float level gauge

  • 浓硫酸液位计

    Concentrated sulfuric acid level gauge

Jiangsu Meant Automation Instrument Co., Ltd.

Mobile: 18936757575 Manager Jiang (same number on WeChat)
Mobile: 13915157170 Manager Pan (same number on WeChat)
Mobile phone: 18052362775 Manager Gu (same number on WeChat)
Jiangsu, Zhejiang and Shanghai agents: 13151342466 Manager Wei (same number on WeChat)
Technology: 13151342466 Manager Zhang (WeChat same number)
Phone: 86-0517-86951208
Phone: 0517-86997027
Phone: 0517-86856332
Fax: 86-0517-86997010
Address: Shenhua Avenue, Jinhu County, Huaian City, Jiangsu Province

Copyright Jiangsu Meant Automation Instrument Co., Ltd. 苏 ICP 备 17042927 号 -2