Sulfuric acid tank level gauge

_Sulfuric acid tank level gauge manufacturers price

The sulphuric acid tank level gauge is connected to the container through gas and liquid connection flanges. According to the principle of buoyancy and magnetic coupling, the magnetic float in the measuring cylinder drives the two-color flip column on the external display of the measuring cylinder to rotate 80 with red (reverse rotation of 180 to display white) as the measured liquid level rises (lowers). And display the purpose of the liquid level position.
Quality Assurance: Signing service, 2 years warranty. After-sales service: fast response, patient guidance, careful service, genuine treatment

  • product description

Side mounted magnetic flap level gauge.Jpg

 

Each flap on the indicating rail is equipped with permanent magnets to protect the level gauge from shock, vibration and high temperature. In addition, moisture and / or aggressive environments are no problem for this level gauge.
This magnetic level gauge has plastic or stainless steel flaps. The flaps can be housed in plastic, aluminum or stainless steel enclosures.

Sulfuric acid tank level gauge overview:
通过气相和液相连接法兰与容器相连接。 The sulfuric acid tank level gauge is connected to the container through gas-phase and liquid-phase connection flanges. According to the principle of buoyancy and magnetic coupling, the magnetic float in the measuring cylinder drives the two-color flip column on the external display of the measuring cylinder to rotate 80 with red (reverse rotation of 180 to display white) as the measured liquid level rises (lowers). And display the purpose of the liquid level position. Each magnetic flip column is a two-color axially symmetric structure. The distance between the two magnetic flip columns is 10mm. White and red are used to indicate the gas phase and liquid phase. You can also choose the lower red to indicate the liquid portion and the upper white to indicate the gas portion. The junction between red and white is the boundary between the liquid and gas phases. The level gauge can also be used for interface measurement of two different density media.
This product complies with HG / T2742-1995 standard.

技术优点: Technical advantages of sulfuric acid tank level gauge :
UHZ series magnetic flap level gauge uses 1Cr18Ni9Ti, 316L, 0Cr18Ni9Ti, 1Cr18Ni9Ti lined with PTFE (polytetrafluoroethylene), PVC, PP and other materials and imported components. It has excellent reliability and corrosion resistance. Its characteristics are very significant:
1.Simple design, compact, sturdy and reliable, long life, no maintenance workload can be installed and used outdoors for many years;
2. The measuring tube is completely isolated from the liquid level display part, the liquid level transmitter, and the alarm switch in terms of pressure and gas resistance;
3. Wide working pressure range, withstand pressure from vacuum to 42MPa;
4. Wide working temperature range, applicable from -190 ~ + 450 ℃;
5.Widely used in the measurement of strong and weak corrosive, flammable and explosive, toxic, strong radioactive, agitated and dirty liquid level;
6. Each model can be optionally equipped with a non-derived ON / OFF alarm switch to achieve automatic control or alarm of high and low liquid levels;
7. Each model can be optionally equipped with 4-20mADC liquid level sensor to achieve long-distance centralized measurement and control.
8. Explosion-proof grade: Meet the requirements of ExibⅡCT5.

Product Features of Sulfuric Acid Storage Tank Level Gauge:

It is suitable for liquid level and boundary measurement of pressure vessels. It can integrate on-site instructions, remote transmission and control alarm.

The instructions are novel, the readings are intuitive and eye-catching, and the viewing angle can be changed according to the user's convenience.

Large measuring range, not limited by the height of the tank.

The indicating mechanism is completely isolated from the measured medium, so it is well sealed, highly reliable and safe to use.

High temperature resistance, non-fading ceramic columns can be used.

Simple structure, easy installation and low maintenance cost.

A. Basic type:

Measuring range:

300 ~ 15000mm

measurement accuracy:

5.0mm, 10mm

Operating temperature:

-40 ~ 250 ℃ (ABS PP-R, PVC: -40 ~ 80 ℃) Special type can reach 450 ℃

作压力: Working pressure:

≤2.5MPa (other than 2.5MPa can be set separately)

Anticorrosive type:

≤0.6MPa

Medium viscosity:

≤1st (10-4m2 / s)

Medium density:

≥450kg / m3

Medium density difference:

≥ 150kg / m3

Sewage interface:

ZG1 / 2 "(inside)

Environmental vibration:

Frequency≤25Hz, amplitude≤0.5mm

Following speed:

≤0.08m / s

Wetted material:

Stainless steel (1Cr18Ni9Ti, 316, 316L)

Stainless steel lined with PTFE (1Cr18Ni9Ti lined with PTFE,)

PVC plastic (polyvinyl chloride), PP-R, ABS

Connection process: side-mounted HG20592-97 DN25 PN4.0 (or user specified)

Top-mounted HG20592-97 DN100 PN1.6 (or user specified)

Jacket flange HG20592-97 DN15 PN1.6 (or user specified)


结构及工作原理 Structure and working principle of sulfuric acid tank level gauge

1.Basic type
According to the principle of buoyancy, the float moves up and down with the rise and fall of the liquid level in the measuring tube. The * magnetic steel in the float drives the red and white flip columns to turn 180 through the coupling effect. , It will change from red to white when descending, so as to realize the level indication.
2. Telefax
Install a transmitter on the float level gauge, move the float up and down, and make the measuring element in the guide rod act sequentially by magnetic coupling to obtain the change in resistance signal, and convert it into a standard signal output of 0-10mA or 4-20mA, and display Instrument or computer connection for remote transmission.
3. Upper and lower limit switch output
The controller is set on the upper and lower limit positions of the level gauge riser by the user. The controller has a self-retaining reed switch. When the magnetic float is used to move the reed switch with the liquid level, the alarm or limit is realized. Bit control.

 

Schematic diagram.Jpg
系统构成及接线 Structure and wiring of sulfuric acid tank level gauge system
1. Upper and lower limit switch output
It consists of a self-retaining reed switch and a converter. The reed switch and the converter are respectively installed in the field and the control room. The converter provides three pairs of contact switches.
2. Telefax
It consists of a measurement unit and a transmission unit.
3.Intrinsically safe explosion-proof
a With intrinsically safe explosion-proof, upper and lower limit switch output type
Explosion-proof switches are composed of reed switches and safety barriers with relay contacts, which can provide users with a pair of normally open or normally closed contacts directly. If users need more contacts, they can be specially designed and ordered. (Figure III)
b With intrinsic safety explosion-proof remote transmission type
Suitable for use in ∏-type electrical equipment (factory use), Class C gas, * surface temperature group T4 (135 C). (Figure 4)
c Precautions for use
① The transmitter housing is provided with an external ground. The user must be reliably grounded during use.
② The use of safety barriers should be in accordance with the relevant instructions.
③ The connection cable between the transmitter and the intrinsically safe end of the safety barrier is a two-core shielded cable with a core wire cross-sectional area of> 0.5m and a permitted distributed capacitance of the cable of 0.8 μF.

 

Outline structure diagram.Jpg
Sulfuric acid tank level meter:

MAT-UHZ- Magnetic flap level gauge
Installation method C Side mount
D Top mounted

The main material 1 304 stainless steel
2 316L stainless steel
3 Teflon lining
4 other

pressure Actual value of working pressure (unit: MPa )

Output type 1 Basic type
2 With upper and lower limit switch output
3 输出, 24V AC Remote transmission with power ( 4 ~ 20mA output, 24V , AC )
4 输出, 24V AC With explosion-proof remote transmission ( 4 ~ 20mA output, 24V , AC )
5 协议型( 4~20mA 输出, 24V AC With HART protocol type ( 4 ~ 20mA output, 24V , AC )

Flange standard DN20 PN1.6MP a HG25902-97 S1 : DN20 PN1.6MP a HG25902-97
实际现场需求 S2: DN25 PN1.6MP a HG25902-97 (Sn: actual site requirements )

Measuring range: 0-6000mm

Drain valve A: 321
B: 304 (commonly used)
C: 316
D: PVC
E: 304 PTFE lined (commonly used for anticorrosion)

Explosion-proof grade normal type
X: intrinsically safe ExibBT4

Working temperature ℃ XX

Related Products
  • 防腐磁翻板液位计

    Anticorrosive magnetic plate level gauge

  • 耐酸碱磁翻板液位计

    Acid and alkali resistant magnetic plate level gauge

  • 不锈钢磁翻板液位计

    Stainless steel magnetic level gauge

  • 4-20mA输出磁翻板液位计

    4-20mA output magnetic flap level gauge

  • 上下限报警磁翻板液位计

    Upper and lower limit alarm magnetic flap liquid level gauge

  • 带报警磁性浮子液位计

    Magnetic float level gauge with alarm

  • 硝酸液位计

    Nitric acid level gauge

  • 远传型磁性浮子液位计

    Remote transmission magnetic float level gauge

  • 侧装式磁性浮子液位计

    Side mounted magnetic float level gauge

  • 浓硫酸液位计

    Concentrated sulfuric acid level gauge

Jiangsu Meant Automation Instrument Co., Ltd.

Mobile: 18936757575 Manager Jiang (same number on WeChat)
Mobile: 13915157170 Manager Pan (same number on WeChat)
Mobile phone: 18052362775 Manager Gu (same number on WeChat)
Jiangsu, Zhejiang and Shanghai agents: 13151342466 Manager Wei (same number on WeChat)
Technology: 13151342466 Manager Zhang (WeChat same number)
Phone: 86-0517-86951208
Phone: 0517-86997027
Phone: 0517-86856332
Fax: 86-0517-86997010
Address: Shenhua Avenue, Jinhu County, Huaian City, Jiangsu Province

Copyright Jiangsu Meant Automation Instrument Co., Ltd. 苏 ICP 备 17042927 号 -2